Aller au contenu

Fredmas

Membres confirmés
  • Compteur de contenus

    906
  • Inscription

  • Dernière visite

  • Jours gagnés

    17

Tout ce qui a été posté par Fredmas

  1. Nico, je ne suis pas le plus expert Fibaro, mais quand même je n'ai pas mis ça au hasard :
  2. This update features migration process from version 3.600, reconfiguring every device, adjusting them for changes which took place in the system. This will assure a possibly smooth transition and continuous operation, allowing each device to work with old settings until reconfiguration is done. Please, refer to the message that appears in the interface and Notification Center for further instructions after finishing upgrade. Important! Updating from version 3.600 may take up to 30 minutes. Do not restart controller during update process. Resolved issues: - No chart of recovery memory. - Problem with email addresses in Home Center Wizard. - Incorrectly displayed negative temperature in rooms tab. - Force remove of devices do not work in Czech. - Minor graphic fixes. Additional information: - Due to a technical issue with NEST plugin we are forced to turn off the plugin for some time. Works on certification for NEST have already started. The plugin will be available as soon as possible. Version 4.102 BETA Resolved issues: - Inability to change the default room sensor. - Error 503 during system startup. - Lack of temperature and humidity data in a view of a room. - Problems with creating backup. - Disabled devices included in the temperature panel. - Time is not updated after changing location. - Improved event panel filtering. New devices support: - Remotec ZXT-120 versions 1.2, 1.1, 1.0, 1.3, 1.7, 1.12, 1.20, 1.21. Additional information: - Suggesting predefined scenes - due to problems with the stability of this functionality it has been disabled for the time being. All previously created scenes will be automatically removed. Version 4.101 BETA Resolved issues: - Problems with Logitech Harmony plugin. - Faulty configuration of parameters of Heatit Thermostat v1.2. - Disappearing backups. - Global Cache stops working. - Incorrect device counting in Dashboard bar. - #0002195: Low Battery Level Indication on new batteries. - #0002267: Upgrade message inconsistent. - #0002270: zwave.me products not working. - #0003909: xml 448 - adding Meter support on endpoints. - #0004075: Hidden slave devices of RGB become unhidden after rebooting. New devices support: - Popp Thermostat v1.0. - Gerda lock v1.2. - Russound XSource. - Russound XZone4. - Zipato RFID in version AU, IN and RU. Other improvements: - Home Center Wizard - wizard used to set basic Home Center data - user configuration, firmware upgrade, alarm configuration and localization - available only for admin user. - For safety reasons, the admin user format was force changed to an email address format. - For safety reasons, the default admin password was force changed. - Choice of weather information source - the possibility to set various sources of weather in Home Center system, as a part of the update two sources were added: Yr.no and Yahoo. As a source of weather information you can also use other devices, e.g. temperature sensor. - Suggesting predefined scenes of turning on light when motion is detected in a room - simply activate a scene to enable the functionality. - Interactive PUSH notifications for mobile applications - a new block in scenes capable of running a scene PUSH notifications. - Extended information about the power consumption - the list of devices available from the Dashboard bar - Many devices such as switches and dimmers can be synchronized. They will react identically to action from both a button and the interface. Synchronization is possible from the advanced settings of one of the devices. - Improved the display of system status. - Change in NEST plugin authentication - NEED TO REINSTALL THE PLUGIN. - Change in Logitech Harmony plugin authentication - NEED TO REINSTALL THE PLUGIN. - Redesigned NEST plugin display - devices in the system correspond to physical devices. - Simplified control of scenes from the web interface. - Change in system notifications functionality - the list of notifications available from Dashboard bar. - Change in information about devices with low battery - the list of devices available from the Dashboard bar. - Extensive scenes and devices filtering - the ability to show all, hidden or only visible devices and scenes. - Change in information about incorrect communication with a device. - Rooms synchronization as a part of Gateway Connections functionality. - Functionality of copying scenes. - Functionality of energy consumption data export (CSV file). CHANGES INTRODUCED IN VERSION 4.X: - Drag & Drop for devices and scenes - available on home, devices and rooms screens. Assigning devices to rooms and changing its order is now much easier and faster. - Temperature Panel - allows to see history of temperature changes in rooms and on each device. - Diagnostic Panel - general information about HC working condition like CPU & RAM usage, free space on hard drive. Will be extended in future versions. - Soft Device Reconfiguration - option allows to save settings, parameters and device ID. Thanks to that scenes with reconfigurable device will not require editing. Full reconfiguration will remove and add the device to the Z-Wave network, resulting in the loss of its settings, parameters and change the device ID.. - Mesh Network Reconfiguration - available on Configuration -> Z-Wave Network - New Z-Wave engine - redesigned and rewritten from the scratch. Now is faster and has better support for devices. - Z-Wave Door Locks support - controlling and PIN settings. - Thermostats - extended controlling for thermostats from manufacturers like: Honeywell, Trane Corporation. - Extended tamper for sensors - exclusive information for motion detection and violation of sensors. - Fibaro Smoke Sensor extended support - level of smoke and gap to alarm level is reported and visible on charts. Sensitivity level is now easier to set. - Fibro Motion Sensor new device - when seismometer mode is turned on new device reporting tremors is available. Charts for temperature and illuminance. Additionally information about sensor violation. - Device hiding - device that is not in use can be hide without removing it. - Device deactivation - deactivated device is visible in UI but can't be controlled. - Multithreading added for HC (server and z-wave) - now engines work much faster. - Event panel moved - for better usability now is available in menu on right side of screen. - Pre-Update Confirmation - installing update will prompt user additional confirmation. - Added support for American English (EN-US) - User rights management - moved to Configuration. - Recovery Memory Health - can be checked on Backup & Recovery - Backups has information about compatibility with current HC version - Block scenes improvements - for device only available actions are visible, scene activation block added and logical conditions grouping using brackets. - Lua Scenes - updated tool-tips for devices. - Rest API Active Documentation - documentation and ability to test REST API requests, access at HOME_CENTER_IP/docs Plugins: - Plugins are grouped in categories: Safety, Cameras, Climate, Multimedia, Others - Plugins search - Network devices search via ARP Plugins category Safety: - Modular Alarm Plugins category Cameras: - more than 130 devices from various manufacturers Plugin category Climate: - Carrier Furance - WS Davis Vantage - Nest - plugin for well-known thermostat - Netatmo - plugin for thermostat and weather station from netatmo Plugins category Multimedia - LG Bluray - LG TV* - NC + mediabox, compatible devices: mediaBOX+ (ITI-3740SX, ADB-3740SX) and turboBOX+ (ITI-5720SX, ADB-5720SX) - XBMC Remote Control - Denon Amplifier - LG Bluray - Onkyo Amplifier - Philips Bluray - Pioneer Amplifier - Samsung TV* - Sonos - Sony Bluray - Sony TV* - Logitech Harmony - DENON HEOS 3/link - Russound X5 Controller - Nuvo Gateway/NV-P3100/NV-P3500/P100/P200 * some TV Sets firmware version may not be supported Plugins category Other - Philips Hue - Wake on LAN - Planika Fireplace Other changes, many other improvements to the system.
  3. Fredmas

    Portier Doorbird

    Pareil. J'arrive à créer un portier sous HCL (fallait trouver que c'était planqué dans les modules liés de l'interface Fibaro). Par contre je n'arrive pas à importer le son. Mais bon me concernant, je ne cherche pas spécialement à remplacer le client Doorbird qui marche très bien.
  4. Fredmas

    Portier Doorbird

    Je n'ai pas encore pris le temps de tester l'intégration du son. Et je ne sais pas si c'est le fait d'avoir une HCL et pas une HC2, mais je ne trouve pas la fonction portier dans l'interface fibaro. J'ai intégré la vidéo du portier comme une caméra. Il faut que je regarde un peu mieux dès que je pourrais.
  5. Sans vouloir faire de hors sujet, je vais suivre votre post car j'ai également une De Dietrich Diematic à condensation de moins de 2 ans. Par contre j'ai 100% de vannes LC13 pour gérer le chauffage de chacune des pièces, avec un circuit de délestage. Alors pas réellement besoin de piloter complètement la chaudière. Mon questionnement et mes doutes concernent davantage le "bon" réglage de la chaudière pour que la modulation se fasse intelligemment et apporte toujours de l'eau à "bonne" température dans le circuit.
  6. Je ne peux pas te dire, car je ne connais pas encore bien ce module, que je n'ai pas. D'ailleurs au passage en fouinant sur le forum, je viens de tomber sur celui-là : http://www.domadoo.fr/fr/peripheriques/2921-aeon-labs-detecteur-multifonctions-6-en-1-multisensor-z-wave-plus-gen5-1220000013100.html qui a l'air de remplir les fonctions également. Grrrrr je me dis qu'on a beau chercher, en fait il est difficile de trouver et comparer les modules qui existent pour une fonction. La preuve j'en trouve encore un autre
  7. Intéressante avec sa remontée d'info. Mais elle ressemble trait pour trait à la DANFOSS LC13 ? Est-ce une copie ? Un partenariat ? Une nouvelle marque du groupe ?
  8. Oui et que j'ai découvert qu'on pouvait ouvrir certaines notifications
  9. Mince. Je ne pensais pas que c'était lié à la HCL. Ce message est dans le centre de notification depuis que j'ai migré en 4.100. EDIT : Ho la grosse nouille !!! Je viens de voir qu'en fait je pouvais cliquer dessus. Ca m'a ouvert un pop-up indiquant que j'étais passé en 4.X et qu'il y a plein de nouveautés, avec une case don't show again. Du coup je n'ai désormais plus cette notification.
  10. Bonjour à tous. Désolé de vous embêter en reposant ma question, mais c'est juste pour savoir si c'est normal chez moi. Vous avez aussi cette notification de migration toujours en cours au bout de 2 mois ?
  11. Etrange effectivement. Je n'ai pas modifié les réglages de toutes mes LC13, et je n'ai pas ton problème.
  12. Enfin pour le moment ma HCL est stable et mon budget est réservé pour d'autres choses. J'arrive à faire presque tout ce que je veux, et j'arrive parfois à contourner avec des scènes et VD. Mais bon, c'est vrai qu'on est quand même limité avec la HCL dès qu'on veut faire un peu plus
  13. OK, donc si on a une HCL et pas de LUA, ça semble compliqué que la consigne de la RS soit reportée sur des LC13 Pis ce n'est pas avec une scène en mode bloc que j'arriverai à prendre en compte la consigne RS pour ordonner une LC13
  14. Belle ouverture d'esprit pour ce forum à la base Fibaro
  15. Je n'ai pas de RS Je pose la question pour comprendre le fonctionnement du matériel avant de potentiellement le commander
  16. Bonjour, Devons-nous comprendre que sans LUA il n'est pas possible que la consigne du RS soit envoyée : - soit à une LC13 directement - soit à une pièce du panneau de chauffage pour que ce dernier modifie la LC13 Un peu comme Nico j'utilise le panneau de chauffage qui convient à mon besoin, et je suis en 100% LC13 avec un petit circuit de délestage derrière la chaudière. Pour le côté waf cette sonde RS est intéressante si elle permet de changer la consigne de la LC13 de la même pièce.
  17. Du coup j'ai une autre question. Depuis que je suis passé de la 3.600 à la 4.100 j'ai découvert le centre de notification. Et depuis l'update, j'ai toujours une notification de migration en cours. Est-ce normal ? Vous aussi ?
  18. Et encore un VD de plus que je ne pourrais pas installer sur ma HCL... Yohan m'avait pourtant prévenu lorsque j'hésitais à investir dans un HC2 ou acheter une HCL
  19. Statut du serveur:61d, 12h, 30m sans problème. Par contre je sais que je ne suis qu'en HCL, mais quand je lis vos RAM ça rend jaloux car de mon côté c'est 95% tout le temps Et pourtant j'ai encore une petite installation...
  20. Fredmas

    Portier Doorbird

    Bien vu Alex ! Je n'étais pas tombé dessus. Il faudrait que je surveille plus régulièrement
  21. Concernant la précision je suis d'accord avec vous. Je ne cherche pas le 0.1 °C. Par contre je ne souhaite pas non plus 2 °C d'erreur si possible. J'ai pensé à Netatmo et Oregon, mais pas Zwave alors je me suis dit que j'allais galérer un peu à les intégrer proprement comme capteur de température et capteur d'humidité. Du coup, il me restait Motion Sensor et ST814, et désormais ce troisième choix SES 303.
×
×
  • Créer...