  1. Dear users, Thank you for using our gateway! Be sure to update to the latest version to enjoy new features and improvements. Main features: 1. A new, user-friendly wizard for adding Elero devices Device configuration within the pairing process. Pairing multiple devices in one process. Redesigned default icons. 2. Configuration of favourite positions in device settings Advanced tab Easy, single-button step-by-step wizard. Possibility to name positions and use them in scenes and profiles. What's new: Access Mobile device status indication. Dashboard Distinction of actions sent on click and hold of the slat rotation button. Support for holding the level change button on device sidebar. Favourite positions buttons available on device sidebar. Devices Possibility of enabling inversion in device Advanced tab for blinds/shutters/gates etc. Improved and unified support of device control types. New default icons for switches, dimmers, shutters, gates, and garage doors. Added icons for missing device states (favourite positions, brightening, dimming, etc.). Devices of the com.fibaro.baseShutter type available in the Blinds linked device. Improved detecting if device is awake and checking its wake-up interval.** Added missing support for FIBARO Roller Shutter 2 FGRM-222.** Reinterview process optimisation.** Elero* Configuration of device name, assignment, and its type as a part of pairing process. Possibility of pairing multiple devices of different types in one process. Testing the device detected during the pairing process to allow its identification. Inversion feature enabled by default for devices detected as awnings. Support for controlling the slats position. Support for alarms and notifications. Possibility of configuring favourite positions. Possibility of changing the device role. Possibility of forcing the device polling. Support for Elero Unio-868, Combio-868 HE, and Combio-868 LI. Energy New Ecology tab for ecu-enthusiasts and everyone who produces energy. Displaying self-sufficiency level, equivalent trees planted, and CO2 reduction. Animated graphs of achievements and their impact on the environment. Possibility of setting the return rate in Panel Settings. Calculation of already returned installation cost including set return rate. Redesigned interface for configuring additional rates in Tariffs. Network Access Point remains enabled after finishing FTI if no network is connected. Nice* Improved and unified support of Nice Mono devices. Global abort for all types of binding procedures. Possibility of configuring favourite positions. Possibility of changing the device role. Possibility of forcing the device polling. Quick Apps Possibility of adding custom icon for all single-state devices (players, remotes, etc.). Bug fixes: Alarm Alarm partitions (com.fibaro.alarmPartition) are not available as zones in alarm panel. Dashboard Holding the button on device sidebar does not work in mobile app. Devices Device properties and its interfaces are removed after the soft reconfiguration. Soft reconfiguration of the device removes it from the linked device. Maximum value reported by the sensor connected to analog input is limited to 4 digits. In some cases, com.fibaro.baseShutter type device lose its configuration. Incorrect setpoint temperature range for some thermostats. Attempt to update firmware of some battery devices always fails. Node provisioning list is not available.** No power charts for power meters (com.fibaro.powerMeter). Elero* Incorrect default polling time interval. Device is too early marked as dead but remains available. Number of devices is not updated after removing the device. In some cases, adding one device after another results in error. In some cases, adding previously removed device is not possible. Device polling is not stopped after performing action. No Notifications tab. Energy No validation for entering negative values of measured energy. Gateway Connection Rebooting the master gateway always results in sending devices model to slaves. Firmware update possibility disappears for devices added to slaves. Nice* In some cases, adding a new device is aborted before finishing the process. Number of devices is not updated after removing the device. No parameters after adding a device with parameters interface. Device added on previous versions has its parameters disabled after performing update. In some cases, clicking on remotes while binding is not always detected. Redundant requests during device creating process. No device calibration for BiDi Dimmer device. Cannot bind new gate using its remote. Incorrect default polling time value. Notifications System migration notification is restored and created after each reboot. Other Some HTTP requests do not require authentication. Plugins Recording feature in FIBARO Intercom plugin does not work. Profiles Some Elero devices are not available in profiles. Scenes No possibility to define multiple values in the date field. Known issues: Z-Wave engine 3.0 Some Z-Wave devices are not fully compatible with the new version of Z-Wave engine. Gateway connection is not available in the new Z-Wave engine version. * - does not apply to HC3L (Home Center 3 Lite) ** - applies only to Z-Wave Engine 3.0
  2. @fredoki : sur un 6s, je n'ai pas constaté ce bug (ios 12.5.5) Stef
  3. je vais tester avec un fgms neuf et voir si le problème persiste... ? Stef
  4. intéressant ! mais j'avoue n'avoir pas effectué de vérif sur l'heure car je ne l'utilise pas Stef
  5. merci Henry pour le lien va falloir que je balade plusieurs FGMS pour en avoir le coeur net ! Stef
  6. j'ai des des problèmes de com avec des FGMS... (ou pure hasard ?) problèmes survenus lors de cette maj Stef
  7. Autant l'appli de la HC2 servait de vitrine pour Fibaro, autant la nouvelle fait pâle figure à côté ! Stef
  8. excellente présentation ! Stef
  9. bon et bien si c'est validé par la haute autorité du WAF, c'est nickel Stef
  10. et la suite Stef
  11. comme ceci ? Stef
  12. MAJ effectuée et en effet tout est plus rapide et fluide ! Stef
  13. couillerot

    Alarme AJAX

    Désolé pour la réponse tardive. non, pas d'accès à internet chez toi = plus accès aux réglages via ton navigateur (sur PC) mais via ton mobile certainement. Stef
  14. mieux vaut tard que jamais... vu que je devais changer le module par un shutter 3. comme je l'avais dit précédemment, j'ai rallongé les câbles d'origines pour faciliter le montage/démontage. Stef
  15. thanks jang for your alternative code ! it's really interesting Stef
  16. complètement d'accord avec toi Lazer ! Stef
  17. Parfait ! Le QA est loin d'être optimisé car il s'agissait du deuxième ou troisième QA/VD que je codais donc débutant inside... Stef
  18. merci pour cette précision Lazer Stef
  19. oui j'imagine... Stef
  20. en fait day1 = tonumber(day) Stef
  21. Pour récupérer l'id d'un icon : - clic droit sur l'icon téléversé / "Ouvrir l'image dans un nouvel onglet" - dans l'adresse du navigateur, tu vas avoir ce genre de chose : http://xxx.xxx.xxx.xxx/assets/userIcons/devices/User1030/User1030100.png - "1030" est alors l'id de l'icon Pour ta deuxième question, je n'en sait rien mais je suppose que non... Stef
  22. on ne peut pas directement ajouter les icons dans le QA. Pour ce faire, il faut ajouter les icons météo via un module z-wave par exemple. Ensuite, il suffit de récupérer les id de chaque icons (en suivant l'ordre pré établi) et pour finir renseigner les id des icons dans le panneau des variables du QA. je ne sais pas si j'ai été assez clair... (?) Stef
  23. day1 est aussi en local sauf qu'il ne figure pas dans cette déclaration Stef
  24. en effet, tu peux très bien supprimer les deuxièmes lignes c'était juste pour être sûr que j'avais bien un number et non un string (c'était mes premiers pas en lua). Stef
  25. pas de soucis si je peux répondre à tes questions Stef
×
×